Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
ACS Omega ; 8(40): 37302-37308, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37841117

RESUMO

Low-field nuclear magnetic resonance (NMR) spectroscopy, conducted at or below a few millitesla, provides only limited spectral information due to its inability to resolve chemical shifts. Thus, chemical analysis based on this technique remains challenging. One potential solution to overcome this limitation is the use of isotopically labeled molecules. However, such compounds, particularly their use in two-dimensional (2D) NMR techniques, have rarely been studied. This study presents the results of both experimental and simulated correlation spectroscopy (COSY) on 1-13C-ethanol at 34.38 µT. The strong heteronuclear coupling in this molecule breaks the magnetic equivalence, causing all J-couplings, including homonuclear coupling, to split the 1H spectrum. The obtained COSY spectrum clearly shows the spectral details. Furthermore, we observed that homonuclear coupling between 1H spins generated cross-peaks only when the associated 1H spins were coupled to identical 13C spin states. Our findings demonstrate that a low-field 2D spectrum, even with a moderate spectral line width, can reveal the J-coupling networks of isotopically labeled molecules.

2.
Sci Rep ; 12(1): 17993, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36289267

RESUMO

Magnetoencephalography (MEG) is a functional neuroimaging technique that noninvasively detects the brain magnetic field from neuronal activations. Conventional MEG measures brain signals using superconducting quantum interference devices (SQUIDs). SQUID-MEG requires a cryogenic environment involving a bulky non-magnetic Dewar flask and the consumption of liquid helium, which restricts the variability of the sensor array and the gap between the cortical sources and sensors. Recently, miniature optically pumped magnetometers (OPMs) have been developed and commercialized. OPMs do not require cryogenic cooling and can be placed within millimeters from the scalp. In the present study, we arranged six OPM sensors on the temporal area to detect auditory-related brain responses in a two-layer magnetically shielded room. We presented the auditory stimuli of 1 kHz pure-tone bursts with 200 ms duration and obtained the M50 and M100 components of auditory-evoked fields. We delivered the periodic stimuli with a 40 Hz repetition rate and observed the gamma-band power changes and inter-trial phase coherence of auditory steady-state responses at 40 Hz. We found that the OPM sensors have a performance comparable to that of conventional SQUID-MEG sensors, and our results suggest the feasibility of using OPM sensors for functional neuroimaging and brain-computer interface applications.


Assuntos
Hélio , Magnetoencefalografia , Magnetoencefalografia/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Neuroimagem , Neuroimagem Funcional
3.
J Magn Reson ; 305: 138-145, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31280186

RESUMO

Magnetic resonance imaging in ultra-low fields is often limited by mediocre signal-to-noise ratio hindering a higher resolution. Overhauser dynamic nuclear polarisation (O-DNP) using nitroxide radicals has been an efficient solution for enhancing the thermal nuclear polarisation. However, the concurrence of positive and negative polarisation enhancements arises in ultra-low fields resulting in a significantly reduced net enhancement, making O-DNP far less attractive. Here, we address this issue by applying circularly polarised RF. O-DNP with circularly polarised RF renders a considerably improved enhancement factor of around 150,000 at 1.2 µT. A birdcage coil was adopted into an ultra-low field MRI system to generate the circularly polarised RF field homogeneously over a large volume. We acquired an MR image of a nitroxide radical solution with an average in-plane resolution of 1 mm. De-noising through compressive sensing further improved the image quality.

5.
Sci Rep ; 8(1): 145, 2018 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-29317689

RESUMO

Emission of radiation from electrons undergoing plasma oscillations (POs) at the plasma frequency has attracted interest because of the existence of intriguing and non-trivial coupling mechanism between the electrostatic PO and the emitted electromagnetic wave. While broadband emission from plasma waves in inhomogeneous plasma is well known, the underlying physics of narrowband emission at the plasma frequency observed in experiments and in solar radio-bursts is obscure. Here we show that a spatially-localized plasma dipole oscillation (PDO) can be generated when electrons are trapped in a moving train of potential wells produced by the ponderomotive force of two slightly detuned laser pulses that collide in plasma and give rise to a burst of quasi-monochromatic radiation. The energy radiated in the terahertz spectral region can reach an unprecedented several millijoules, which makes it suitable for applications requiring short pulses of high-intensity, narrowband terahertz radiation.

6.
Biochem Biophys Res Commun ; 490(2): 460-465, 2017 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-28623132

RESUMO

Glyoxalase 1 (Glo1) is the first enzyme involved in glutathione-dependent detoxification of methylglyoxal, eventually generating d-lactate by the second enzyme glyoxalase 2 (Glo2). An accumulation of intracellular glyoxal and methylglyoxal leads to protein malfunction and mutation via formation of the advanced glycation end products (AGEs). Studies on mouse behavior suggest that methylglyoxal has anxiolytic properties. In this report, we generated and characterized a mouse knockout for Glo1. The knockout mice were viable without a pronounced phenotypic defect. Increased level of AGEs in Glo1 knockout mice was detected by immunoblotting with anti-MGH1 in liver homogenate, but not in brain. Alterations in behavior were observed in open field, light-dark transition, and tail suspension test. Open field data indicate increased exploration for novel environment and entry/stay in center zone in Glo1 knockout mice. In addition, increased light-dark transition and immobility was observed in the knockout mice. These data indicate that Glo1 knockout reduces anxiety-like behavior, but increases depression-like behavior.


Assuntos
Ansiedade/genética , Depressão/genética , Lactoilglutationa Liase/genética , Animais , Ansiedade/metabolismo , Depressão/metabolismo , Deleção de Genes , Glutationa/metabolismo , Produtos Finais de Glicação Avançada/metabolismo , Glioxal/metabolismo , Lactoilglutationa Liase/metabolismo , Fígado/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Aldeído Pirúvico/metabolismo
7.
Rev Sci Instrum ; 88(4): 044704, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28456227

RESUMO

Magnetoencephalography (MEG) based on superconducting quantum interference devices enables the measurement of very weak magnetic fields (10-1000 fT) generated from the human or animal brain. In this article, we introduce a small MEG system that we developed specifically for use with rats. Our system has the following characteristics: (1) variable distance between the pick-up coil and outer Dewar bottom (∼5 mm), (2) small pick-up coil (4 mm) for high spatial resolution, (3) good field sensitivity (45∼ 80fT/cm/Hz), (4) the sensor interval satisfies the Nyquist spatial sampling theorem, and (5) small source localization error for the region to be investigated. To reduce source localization error, it is necessary to establish an optimal sensor layout. To this end, we simulated confidence volumes at each point on a grid on the surface of a virtual rat head. In this simulation, we used locally fitted spheres as model rat heads. This enabled us to consider more realistic volume currents. We constrained the model such that the dipoles could have only four possible orientations: the x- and y-axes from the original coordinates, and two tangentially layered dipoles (local x- and y-axes) in the locally fitted spheres. We considered the confidence volumes according to the sensor layout and dipole orientation and positions. We then conducted a preliminary test with a 4-channel MEG system prior to manufacturing the multi-channel system. Using the 4-channel MEG system, we measured rat magnetocardiograms. We obtained well defined P-, QRS-, and T-waves in rats with a maximum value of 15 pT/cm. Finally, we measured auditory evoked fields and steady state auditory evoked fields with maximum values 400 fT/cm and 250 fT/cm, respectively.


Assuntos
Encéfalo/fisiologia , Magnetoencefalografia/instrumentação , Animais , Potenciais Evocados Auditivos , Magnetoencefalografia/veterinária , Ratos
8.
AMB Express ; 7(1): 38, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28197984

RESUMO

In this study, we quantified the attachment and detachment of bacteria during transport in order to elucidate the contributions of reversible attachment on bacterial breakthrough curves. The first set of breakthrough experiment was performed for a laboratory sand column using leaching solutions of deionized water and mineral salt medium (MSM) of 200 mM with reference to KCl solution by employing Pseudomonas putida as a model bacterium. In the second set of experiment, the ionic strengths of leaching solutions immediately after bacterial pulse were lowered to tenfold and 100-fold diluted system (2 and 20 mM MSM) to focus on the influence of physicochemical factor. Results have shown that bacterial retention occurred in the sand column due to the physical deposition and physicochemical attachment. The physicochemical attachment was attributed to the high ionic strength (200 mM MSM) of leaching solution and the formation of primary energy minimum. Replacing the 200 mM leaching solution with the lower ionic strengths after pulse resulted in the increased tailing of breakthrough curve due to the detachment from the attached bacteria. The detachment could be well explained by DLVO theory, which showed the formation of energy barrier and disappearance of the secondary minimum as the ionic strength gradually decreased. Analysis of mass recovery revealed that 12-20% of the attachment was due to physical and physicochemical attachment, respectively, where the latter consisted of 25-75% of irreversible and reversible attachment respectively.

9.
Bioconjug Chem ; 28(4): 957-967, 2017 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-28215090

RESUMO

The overuse of antibiotics plays a major role in the emergence and spread of multidrug-resistant bacteria. A molecularly targeted, specific treatment method for bacterial pathogens can prevent this problem by reducing the selective pressure during microbial growth. Herein, we introduce a nonviral treatment strategy delivering genome editing material for targeting antibacterial resistance. We apply the CRISPR-Cas9 system, which has been recognized as an innovative tool for highly specific and efficient genome engineering in different organisms, as the delivery cargo. We utilize polymer-derivatized Cas9, by direct covalent modification of the protein with cationic polymer, for subsequent complexation with single-guide RNA targeting antibiotic resistance. We show that nanosized CRISPR complexes (= Cr-Nanocomplex) were successfully formed, while maintaining the functional activity of Cas9 endonuclease to induce double-strand DNA cleavage. We also demonstrate that the Cr-Nanocomplex designed to target mecA-the major gene involved in methicillin resistance-can be efficiently delivered into Methicillin-resistant Staphylococcus aureus (MRSA), and allow the editing of the bacterial genome with much higher efficiency compared to using native Cas9 complexes or conventional lipid-based formulations. The present study shows for the first time that a covalently modified CRISPR system allows nonviral, therapeutic genome editing, and can be potentially applied as a target specific antimicrobial.


Assuntos
Sistemas CRISPR-Cas , Repetições Palindrômicas Curtas Agrupadas e Regularmente Espaçadas , Edição de Genes/métodos , Genoma Bacteriano , Staphylococcus aureus Resistente à Meticilina/genética , RNA Guia de Cinetoplastídeos/administração & dosagem , Proteínas de Bactérias/metabolismo , Proteína 9 Associada à CRISPR , Endonucleases/metabolismo , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Polímeros/metabolismo , RNA Guia de Cinetoplastídeos/genética , Streptococcus pyogenes/enzimologia
10.
Ther Innov Regul Sci ; 51(1): 111-117, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30235996

RESUMO

BACKGROUND: Fixed-dose combination (FDC) drugs have been an attractive product in pharmaceutical markets because of their unique advantages, but general guidance directing the clinical development of FDC drugs is not yet available in the US. METHOD: All drug approval reports of FDC products approved by the US FDA from January 2010 to December 2015 were intensively analyzed to investigate the regulatory requirements of the US FDA. RESULT: Through analyzing 63 approved FDCs out of 655 New Drug Application (NDA) approvals, it was found that completion of the full phases of clinical trials was not always required for approval by the FDA, which indicates that some phases of clinical studies can be possibly exempted, if justified. CONCLUSION: The results imply that pharmaceutical companies can accelerate FDC development and enter the market earlier if scientific regulatory rationales are established.

11.
J Magn Reson ; 255: 114-21, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25955437

RESUMO

Dynamic nuclear polarization (DNP) allows measuring enhanced nuclear magnetic resonance (NMR) signals. Though the efficiency of DNP has been known to increase at low fields, the usefulness of DNP has not been throughly investigated yet. Here, using a superconducting quantum interference device-based NMR system, we performed a series of DNP experiments with a nitroxide radical and measured DNP spectra at several magnetic fields down to sub-microtesla. In the DNP spectra, the large overlap of two peaks having opposite signs results in net enhancement factors, which are significantly lower than theoretical expectations and nearly invariant with respect to magnetic fields below the Earth's field. The numerical analysis based on the radical's Hamiltonian provides qualitative explanations of such features. The net enhancement factor reached 325 at maximum experimentally, but our analysis reveals that the local enhancement factor at the center of the rf coil is 575, which is unaffected by detection schemes. We conclude that DNP in the hyperfine-field-dominant region yields sufficiently enhanced NMR signals at magnetic fields above 1 µT.

12.
Biomed Res Int ; 2015: 385428, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25705658

RESUMO

We investigated T 1 relaxations of ex-vivo cancer tissues at low magnetic fields in order to check the possibility of achieving a T 1 contrast higher than those obtained at high fields. The T 1 relaxations of fifteen pairs (normal and cancerous) of breast tissue samples were measured at three magnetic fields, 37, 62, and 122 µT, using our superconducting quantum interference device-based ultralow field nuclear magnetic resonance setup, optimally developed for ex-vivo tissue studies. A signal reconstruction based on Bayesian statistics for noise reduction was exploited to overcome the low signal-to-noise ratio. The ductal and lobular-type tissues did not exhibit meaningful T 1 contrast values between normal and cancerous tissues at the three different fields. On the other hand, an enhanced T 1 contrast was obtained for the mucinous cancer tissue.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Campos Magnéticos , Modelos Teóricos , Neoplasias da Mama/patologia , Meios de Contraste , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Radiografia
13.
IEEE Trans Biomed Eng ; 62(1): 60-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25020011

RESUMO

A 3-D cardiac visualization is significantly helpful toward clinical applications of magnetocardiography (MCG), but the cardiac reconstruction requires a segmentation process using additional image modalities. This paper proposes a 3-D cardiac outline reconstruction method using only MCG measurement data without further imaging techniques. The cardiac outline was reconstructed by a combination of both spatial filtering and coherence mapping method. The strength of cardiac activities was first estimated by the array-gain constraint minimum-norm spatial filter with recursively updated gram matrix (AGMN-RUG). Then, waveforms were reconstructed at whole source grids, and the maximum source points of an atrium and ventricle were selected as a reference, respectively. Next, the coherence between each maximum source point and whole source points was compared by the coherence mapping method. A reconstructed cardiac outline was validated by comparing with an overlapped volume ratio when the reconstructed volume was identically matched with the original volume. The results obtained by the AGMN-RUG were compared to the results by other spatial filters. The accuracy of numerical simulation and phantom experiment by the AGMN-RUG was superior 10% and 8%, respectively, than the accuracy by the standardized low-resolution electromagnetic tomography. This accuracy demonstrated the efficacy of the proposed 3-D cardiac reconstruction method.


Assuntos
Algoritmos , Diagnóstico por Computador/métodos , Sistema de Condução Cardíaco/fisiologia , Imageamento Tridimensional/métodos , Magnetocardiografia/métodos , Modelos Cardiovasculares , Simulação por Computador , Sistema de Condução Cardíaco/anatomia & histologia , Humanos , Magnetocardiografia/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Rev Sci Instrum ; 85(11): 116105, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430154

RESUMO

An optical receiver system composing 13 serial data restore/synchronizer modules and a single module combiner converted optical 32-bit serial data into 32-bit synchronous parallel data for a computer to acquire 152-channel magnetoencephalography (MEG) signals. A serial data restore/synchronizer module identified 32-bit channel-voltage bits from 48-bit streaming serial data, and then consecutively reproduced 13 times of 32-bit serial data, acting in a synchronous clock. After selecting a single among 13 reproduced data in each module, a module combiner converted it into 32-bit parallel data, which were carried to 32-port digital input board in a computer. When the receiver system together with optical transmitters were applied to 152-channel superconducting quantum interference device sensors, this MEG system maintained a field noise level of 3 fT/√Hz @ 100 Hz at a sample rate of 1 kSample/s per channel.


Assuntos
Computadores , Magnetoencefalografia/instrumentação , Óptica e Fotônica/instrumentação
15.
FEBS J ; 281(24): 5447-62, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25283443

RESUMO

UNLABELLED: DJ-1 family proteins have recently been characterized as novel glyoxalases, although their cofactor-free catalytic mechanisms are not fully understood. Here, we obtained crystals of Arabidopsis thaliana DJ-1d (atDJ-1d) and Homo sapiens DJ-1 (hDJ-1) covalently bound to glyoxylate, an analog of methylglyoxal, forming a hemithioacetal that presumably mimics an intermediate structure in catalysis of methylglyoxal to lactate. The deuteration level of lactate supported the proton transfer mechanism in the enzyme reaction. Differences in the enantiomeric specificity of d/l-lactacte formation observed for the DJ-1 superfamily proteins are explained by the presence of a His residue in the active site with essential Cys and Glu residues. The model for the stereospecificity was further evaluated by a molecular modeling simulation with methylglyoxal hemithioacetal superimposed on the glyoxylate hemithioacetal. The mechanism of DJ-1 glyoxalase provides a basis for understanding the His residue-based stereospecificity. DATABASE: Structural data have been submitted to the Protein Data Bank under accession numbers 4OFW (structure of atDJ-1d), 4OGF (structure of hDJ-1 with glyoxylate) and 4OGG (structure of atDJ-1d with glyoxylate).


Assuntos
Acetais/química , Liases de Carbono-Enxofre/metabolismo , Sequência de Aminoácidos , Liases de Carbono-Enxofre/química , Catálise , Cristalografia por Raios X , Ácido Láctico/metabolismo , Dados de Sequência Molecular , Conformação Proteica , Aldeído Pirúvico/metabolismo , Estereoisomerismo
16.
J Magn Reson ; 246: 4-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25063950

RESUMO

Two-dimensional (2D) spectroscopy is one of the most significant applications of nuclear magnetic resonance (NMR). Here, we demonstrate that the 2D NMR can be performed even at a low magnetic field of less than 5µT, which is ten times less than the Earth's magnetic field. The pulses used in the experiment were composed of circularly polarized fields for coherent as well as wideband excitations. Since the excitation band covers the entire spectral range, the simplest two-pulse sequence delivered the full 2D spectrum. At 5µT, methanol with (13)C enriched up to 99% belongs to a strongly coupled regime, and thus its 2D spectrum exhibits complicated spectral correlations, which can be exploited as a fingerprint in chemical analysis. In addition, we show that, with compressive sensing, the acquisition of the 2D spectrum can be accelerated to take only 45% of the overall duration.

17.
Neuroimage ; 91: 63-9, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24473099

RESUMO

Matching the proton-magnetic-resonance frequency to the frequency of a periodic neural oscillation (e.g., alpha or gamma band waves) by magnetic resonance imaging techniques, enables direct visualization of brain functional connectivity. Functional connectivity has been studied by analyzing the correlation between coherent neural oscillations in different areas of the brain. In electro- or magneto-encephalography, coherent source reconstruction in a source-space is very tricky due to power leaking from the correlation among the sources. For this reason, most studies have been limited to sensor-space analyses, which give doubtful results because of volume current mixing. The direct visualization of coherent brain oscillations can circumvent this problem. The feasibility of this idea was demonstrated by conducting phantom experiments with a SQUID-based, micro-Tesla NMR/MRI system. We introduce an experimental trick, an effective step-up of the measurement B-field in a pulse sequence, to decouple the magnetic resonance signal from the strong magneto-encephalographic signal at the same frequency.


Assuntos
Mapeamento Encefálico/métodos , Ondas Encefálicas/fisiologia , Eletroencefalografia , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Vias Neurais/fisiologia , Algoritmos , Ritmo alfa/fisiologia , Campos Eletromagnéticos , Humanos , Processamento de Imagem Assistida por Computador , Magnetismo , Magnetoencefalografia , Imagens de Fantasmas
18.
J Magn Reson ; 239: 87-90, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24463634

RESUMO

A pulse, which is produced by a single coil and thereby has a linear polarization, cannot coherently drive nuclear spins if the pulse is stronger than the static field B0. The inaccuracy of the pulse, which arises from the failure of the rotating wave approximation, has been an obstacle in adopting multiple pulse techniques in ultra-low field NMR where B0 is less than a few µT. Here, we show that such a limitation can be overcome by applying pulses of circular polarization using two orthogonal coils. The sinusoidal nutation of the nuclear spins was experimentally obtained, which indicates that coherent and precise controls of the nuclear spins can be achieved with circularly polarized pulses. Additional demonstration of the Carl-Purcell-Meiboom-Gill sequence verifies the feasibility of adopting multiple pulse sequences to ultra-low field NMR studies.

19.
FEBS J ; 280(14): 3328-39, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23651081

RESUMO

We examined six Arabidopsis thaliana genes from the DJ-1/PfpI superfamily for similarity to the recently characterized bacterial and animal glyoxalases. Based on their sequence similarities, the six genes were classified into two sub-groups consisting of homologs of the human DJ-1 gene and the PH1704 gene of Pyrococcus horikoshii. Unlike the homologs from other species, all the A. thaliana genes have two tandem domains, which may have been created by gene duplication. The six AtDJ-1 proteins (a-f) were expressed in Escherichia coli for enzymatic assays with glyoxals. The DJ-1d protein, which belongs to the PH1704 sub-group, exhibits the highest activity against methylglyoxal and glyoxal, and K(m) values of 0.10 and 0.27 mm were measured for these two substrates, respectively, while the corresponding k(cat) values were 1700 and 2200 min(-1), respectively. The DJ-1a and DJ-1b glyoxalases exhibited higher specificity towards glyoxal. The other three proteins have either no or extremely low activity for glyoxals. For the DJ-1d enzyme, the residues, Cys120/313 and Glu19/212 at the active site and His121/314 and Glu94/287 at the oligomeric interface were mutated to alanines. As in other enzymes characterized to date, mutation of either the Cys or the Glu residues of the active site completely abolished enzyme activity, whereas mutation of the interface residues produced a variable decrease in activity. DJ-1d differs from its animal and bacterial homologs with respect to the configuration of its catalytic residues and the oligomeric property of the enzyme. When the wild-type DJ-1d enzyme was expressed in E. coli, the bacteria became resistant to glyoxals.


Assuntos
Proteínas de Arabidopsis/química , Arabidopsis/enzimologia , Lactoilglutationa Liase/química , Sequência de Aminoácidos , Substituição de Aminoácidos , Proteínas de Arabidopsis/biossíntese , Proteínas de Arabidopsis/genética , Domínio Catalítico , Dicroísmo Circular , Escherichia coli , Cinética , Lactoilglutationa Liase/biossíntese , Lactoilglutationa Liase/genética , Modelos Moleculares , Dados de Sequência Molecular , Peso Molecular , Estrutura Quaternária de Proteína , Estrutura Secundária de Proteína , Proteínas Recombinantes/biossíntese , Proteínas Recombinantes/química , Proteínas Recombinantes/genética
20.
Rev Sci Instrum ; 84(12): 125109, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24387470

RESUMO

We developed an optical transmission module consisting of 16-channel analog-to-digital converter (ADC), digital-noise filter, and one-line serial transmitter, which transferred Superconducting Quantum Interference Device (SQUID) readout data to a computer by a single optical cable. A 16-channel ADC sent out SQUID readouts data with 32-bit serial data of 8-bit channel and 24-bit voltage data at a sample rate of 1.5 kSample/s. A digital-noise filter suppressed digital noises generated by digital clocks to obtain SQUID modulation as large as possible. One-line serial transmitter reformed 32-bit serial data to the modulated data that contained data and clock, and sent them through a single optical cable. When the optical transmission modules were applied to 152-channel SQUID magnetoencephalography system, this system maintained a field noise level of 3 fT/√Hz @ 100 Hz.


Assuntos
Equipamentos e Provisões Elétricas , Magnetoencefalografia/métodos , Fenômenos Ópticos , Conversão Análogo-Digital , Condutividade Elétrica , Campos Eletromagnéticos , Magnetoencefalografia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...